INSTALLATION AND OPERATING INSTRUCTION MANUAL LCS790LCS790LCS790LCS790 SIREN AMPLIFIER & LIGHT CONTROLLER U
-7- Installation: Dip Switch Settings (cont’d) UP/DOWN DIP Switch Settings BUZ Beep Settings By default, every time a button is pressed on the keyp
-8- Installation: Dip Switch Settings (cont’d) PD Pursuit Disable The farthest right slide switch position is normally used for “pu
-9- Installation: Dip Switch Settings (cont’d) Detailed Programming IN/OUT DIP Switch Settings There are an additional two DIP switches located to t
-10- Option Default Setting Optional Setting Button Operation (Open or Closed) Activating a Button (Turning it on) Will Close The Circuit (apply +
-11- Installation: Detailed Programming Detailed Programming Legend Detailed Programming Legend SLIDE SWITCH POSITION ROTARY KNOB POSITION PUSH BUTT
-12- Detailed Programming Instructions Once you have programmed each option(s) to the desired setting(s), you must flip the PGM DIP switch down to sa
-13- Installation: Detailed Programming Button Operation (Latched or Momentary) Button Operation (Latched or Momentary) All of the buttons, by defau
-14- Advanced Gun Lock Programming Installation: Detailed Programming Gun Lock Button Options Please Note: You must have the Gun Lock DIP switch (
-15- Installation: Detailed Programming Auto Beep Function Please Note: You must have the Beep DIP switch (BUZ) on to use this feature (see page
-16- Installation: Detailed Programming Steady or Pulsed Output Options Pulsed Output Rate If you have set any of the outputs to pulse (as described
-i- INSTALLATION INFORMATION PURCHASE DATE: INSTALLATION DATE: INSTALLER: DEALER: MODEL: LCS790 AMPLIFIER SERIAL NO: CONTROL HE
-17- Installation: Detailed Programming MAN Step Up and HF Sweep Options Manual “Step-Up” Function Time Out By default, when a siren tone is activat
-18- Siren Disable (PA and Horn Functions only) If you desire to COMPLETELY disable the siren feature from this unit, allowing only the PA, Horn, an
-19- Installation: Detailed Programming Standby Mode Standby Mode (Stealth Mode) By default, all of the functions on this unit can be activated at a
-20- Installation: Detailed Programming Slide Switch Auto-Activation of Warn Pattern Slide Switch Activates Warn Pattern (on Traffic Director) Under
-21- Installation: Detailed Programming Basic Slide Switch Auto-Activation of Siren Basic Slide Switch Auto-Activation of Siren Under normal operati
-22- Installation: Detailed Programming Advanced Siren Auto-Activation Advanced Siren Auto-Activation (Slide Switch and/or Push Buttons) As indicate
-23- Tone Change Allowed While In Audible Pursuit The default programming for this siren allows you to move the rotary knob and change the tone at
QUICK INSTALLATION CHECKLIST • 8 AWG Wire to Ground Terminal • +12VDC to three Light Power Terminals (Use 8 AWG) • Lights connected to S1-S7 outp
Ground - #8 AWGACTION - VIDEO CAMERA TRIGGER (1A MAX)S7 (20A MAX) - TRAFFIC DIRECTOR RIGHTS4 (20A MAX)S5 (20A MAX) - TRAFFIC DIRECTOR WARNS6 (20A MAX)
-ii- TABLE OF CONTENTS OVERVIEW 1 PRECAUTIONS 2 CONTENTS 2 SPECIFICATIONS 3 INSTALLATION 4-40 INSTALLER-SELECTABLE OPTIONS 4-31 DIP Switch Set
-24- Slide Switch Auto Activation of Push Button Functions (CONT’D) S1-S7 are Red: Functions tied to each Red button (S1-S7) WILL automatically ac
-25- Installation: Detailed Programming Rotary Tones Auto-Activate Slide Switch Functions Rotary Switch Tones Auto-Activate Slide Switch Functions T
-26- Park-Kill De-activation of Functions T The Park-Kill option will automatically shut off the siren when activated by an external switch (i.e. the
-27- High-Low (Two-Tone) Override of Phaser Tone By default, the Phaser tone is enabled on this siren. This tone can be replaced with a High/Low si
-28- Installation: Optional Settings Horn Ring Transfer (HRT) Options HRT Active Mode By default, if you connect the Horn Ring Transfer (HRT) optio
-29- Installation: Optional Settings Action Terminal Output & Traffic Director Compatibility Action Terminal Output Under normal operation, whe
-30- Installation: Optional Settings Traffic Director Compatibility (CONT’D) Traffic Director Compatibility Settings (CONT’D) By default, the COM po
-31- Installation: Optional Settings Reset to Factory Defaults Reset To Factory Defaults If at anytime during the programming, you are unsure of wha
-32- Installation Mounting Mounting SAFETY PRECAUTIONS For the safety of the installer, vehicle operator, passengers, and the community please obse
-1- LCS790 Overview The LCS790 Siren Amplifier is a premium 200W unit designed for single or dual 100W speaker use and full lighting control. T
-33- Installation Electrical Connections Electrical Connections Electrical connections to the unit are made using several terminals and re-movable c
-34- Installation Wiring Connections Wiring Connections Power (+12VDC) and ground connections are made through several terminal blocks on the back o
-35- Installation: Wiring 12-Terminal Connector Slide Switch: Each of these terminals should be connected to the +12VDC device you would like con
-36- Installation Wiring Diagram #1 -BATTERYSiren Wiring Diagram #1Ground - #8 AWGACTION (1A MAX)S7 (20A MAX)S4 (20A MAX)S5 (20A MAX)S6 (20A MAX)S2 (
-37- Installation: Wiring 10-Terminal Connector Park/Kill: (Terminal 1) - Used for the Park/Kill feature that automatically deactivates the siren
-38- Installation: Wiring 10-Terminal Connector (CONT’D) Auxiliary: (Terminal 5) - Used for remote Manual (or Air Horn) control. Using an 18 AWG
-39- Installation Wiring Diagram #2 Negative SideHorn SwitchGround Side Switched HornPositive Side Switched Horn+12 VDCPositive SideHorn SwitchSPEAKE
-40- Label Insertion LABEL INSERTION Once the wire connections have been made to S1-S7, labels can be inserted into the switches. The product
-41- Operation On/Off General This unit is designed for easy operation under the stress associated with high-speed pursuit. Most siren functions an
-42- Operation Rotary Knob PHSR - (Phaser) Ultra-fast changing tone used for maximum attention. YELP - A rapidly changing tone used in congest
-2- Installation Information Precautions Proper installation of the unit is essential for years of safe, reliable operation. Please read all instru
-43- Operation Slide Switch and Push Buttons Slide Switch The slide switch is designed for quick pursuit mode operation. The far left position (OFF
-44- Operation Manual and Air Horn MAN and HORN Buttons The front panel of the LCS790 contains two pushbuttons that operate the Manual function and
-45- Operation Volume Controls, Microphone, & Speaker Diagnostics Volume Controls The radio repeat volume (RADIO) control is recessed in the uppe
-46- Operation: Auxiliary Input and Park-Kill Fuses and Parts Auxiliary Input During installation an auxiliary input may be connected to the vehicle
-47- Service and Troubleshooting Service This unit is designed to provide years of reliable service under even the worst conditions. Many times th
-48- Warranty and Return If you have any questions concerning this or any other SVP product, please contact our Customer Service Department at (585
-49- Returned Goods Authorization Form Returned Goods Authorization Form MODEL: LCS790 Serial RGA No. Number Purchase Install
-3- Specifications Input Voltage 10 - 16 VDC (negative ground) Input Current 8.0 Amps @ 13.6 VDC (single 100W speaker) 16.0 Amps @ 13.6 VDC (dual 100
-4- Installation Signal Vehicle recommends that you bench test the unit immediately after receipt to ensure that it was not damaged in shipping. Th
-5- Installation: Dip Switch Settings (cont’d) UPSIDE DOWN VIEW There are two sets of DIP switches located inside the unit. One set has six swit
-6- Installation: Dip Switch Settings (cont’d) SW LABEL FUNCTION DOWN POSITION (Default) UP POSITION 1 BUZ Beep Setting Keypad buttons beep when pres